Rrr Township
KOKKONDA ASHIS AND OTHERS · Rangareddy · RERA P02400008591
RRR TOWNSHIP is a plotted development in VITAIPALLY, Amangal Mandal, Ranga Reddy District, developed by registered promoter KOKKONDA ASHIS AND OTHERS. The project site is 14,280.59 sq. m, and the tentative layout comprises 41 plots; plot sizes read from the approved drawing range from 126.5–335.13 sq. m (151.3–400.8 sq. yd). It is registered under TG-RERA number P02400008591, and the promoter’s Form B declares completion by 12 June 2026.
01What we found
Read from TG-RERA filings, approvals, land and registration records and court records. A court case is counted only when the court record states this project's survey number with its village, or names the project.
02Check before you pay
13 items to check before you pay, 5 high - from the title chain, court records and approvals, each with what to ask the builder or your advocate. An item may not be a problem with the project: records can be incomplete.
1. Project at a glance
Project identity
| Item | Record |
|---|---|
| Registered project name | RRR TOWNSHIP |
| Project type | Plotted development / tentative layout RERA record |
| Phase or registered portion | Not separately identified; registration is for the project on the stated survey parcels |
| TG-RERA registration | P02400008591 |
| Registration validity | Certificate states validity commencing 06/08/2024 and ending 12/06/2026; this is registration validity, not the current status of any extension |
| RERA status in supplied record | New project; certificate captured 10 September 2026. The supplied evidence does not establish whether registration has since been extended or otherwise changed RERA record Approvals record |
| Registered promoter | KOKKONDA ASHIS AND OTHERS |
Land and geographic identity
| Item | Record |
|---|---|
| Locality | VITAIPALLY RERA filing |
| Revenue village names in project records | Vittaipally Tanda (RERA certificate/header) and Vitaipally Revenue Village / Vitaipally Village (layout approval and title materials) |
| Mandal / district / PIN | Amangal / Ranga Reddy / 509321 |
| Survey numbers and subdivisions | 1400/P, 1401/P, 1402/P and 1404/P |
| Site extent | 14,280.59 sq. m total; 693.71 sq. m affected by road widening; net area stated as 13,586.88 sq. m in the project land record Land records RERA filing |
| Boundaries | North: neighbours’ land; South: neighbours’ land; East: neighbours’ land; West: road RERA filing |
Development identity
| Item | Record |
|---|---|
| Layout sanctioning authority | Amangal Municipality/Municipal Corporation; the filed layout material identifies TS-DTCP, delegated to Amangal Municipality Approvals record |
| Principal approval | Tentative Layout Plan 0010/LO/3134/2024, approved 12 June 2024 |
| Application number | 008479/LO/DTCP/3134/0016/2023 |
| Layout configuration | 41 plots; no buildings or proposed built-up area are specified in the layout approval |
| Approved built-up area | 0.00 proposed built-up area, excluding and including parking, in the filed layout parameters; this is a plotted layout, not a building plan |
| Buildings, floors and parking levels | Not applicable or not disclosed for the plotted-layout approval; no building-floor or parking-level schedule is supplied |
Offering and status
| Item | Record |
|---|---|
| Offering | 41 individual plots in the tentative layout |
| Plot area range | Software-read from the approved drawing: 126.5–335.13 sq. m (151.3–400.8 sq. yd); drawing-derived measurements should be checked against the plan Layout record |
| Booked / available plots | Not established in the supplied RERA evidence RERA unit table |
| Construction stage | No independently verified on-site progress is supplied. The layout approval requires infrastructure and amenities to be completed by 12 June 2026 |
| Promoter-declared completion | Form B undertakes completion by 12 June 2026 |
| Occupancy / completion certificate | No occupancy or completion certificate is identified in the supplied documents; this is a plotted layout Document index |
2. The project story
RRR TOWNSHIP is a plotted residential layout, rather than an apartment or multi-tower development. The RERA certificate identifies the project at Vittaipally Tanda, Amangal, Ranga Reddy, PIN 509321, on Survey Nos. 1400/P, 1401/P, 1402/P and 1404/P. The layout approval describes the site as Vitaipally Revenue Village and records 41 plots.
The approved layout drawing allocates land to plots, internal roads, a park/open space, social infrastructure and utilities. The approval is tentative and makes infrastructure development and the handover of designated areas part of its conditions. The approval sets 12 June 2026 as the initial deadline for infrastructure and amenities; the promoter’s Form B separately declares the same completion date. These are filed/approval commitments, not independent verification that the works have been completed.
The RERA-filed records supplied here do not establish plot-by-plot sales status or current physical progress. No occupancy or completion certificate is provided. RERA unit table Document index
3. Master plan, architecture & building design
This is a 41-plot layout. The filed layout records a site extent of 14,280.59 sq. m, a road-widening area of 693.71 sq. m, and a net layout area stated as 13,586.88 sq. m. Layout record
The layout drawing’s area statement, read by software, allocates the net layout area as follows. These are drawing-derived layout areas, not building or apartment areas:
| Layout use | Area | Share stated/read from drawing |
|---|---|---|
| Plots | 8,668.39 sq. m | 63.80% |
| Roads | 3,209.86 sq. m | 23.62% |
| Parks / organized open space | 1,230.05 sq. m | 9.05% |
| Social infrastructure | 340.87 sq. m | 2.51% |
| Utilities | 137.68 sq. m | 1.01% |
| Amenities | 0.00 sq. m | 0.00% |
Layout record
The approval records internal road widths of 9.14 m and 12 m, as well as a 30.00 m existing road and a 60.00 m proposed road. It reserves plots 31–36 as mortgage plots in favour of the Municipality; the approval records a mortgage area of 1,772 sq. yd.
No building footprint, floors, tower arrangement, apartment plans or building-area schedule is evidenced. The filed layout parameters state proposed built-up area of 0.00 both excluding and including parking.
4. Homes, configurations & floor plans
The RERA-filed offering evidenced in the supplied records is 41 plots. No RERA plot-wise saleable-area schedule, booked/available inventory, or unit-by-unit allotment status is supplied. RERA unit table
The approved drawing’s plot schedule was read by software; its plot sizes are not presented as RERA-filed saleable areas. The drawing-derived size bands are:
| Drawing-derived plot size | Number of plots |
|---|---|
| 150–200 sq. yd (125–167 sq. m) | 15 |
| 200–250 sq. yd (167–209 sq. m) | 9 |
| 250–300 sq. yd (209–251 sq. m) | 6 |
| 300–400 sq. yd (251–334 sq. m) | 10 |
| 400–500 sq. yd (334–418 sq. m) | 1 |
The smallest software-read plot is 126.5 sq. m (151.3 sq. yd), the median is 190.21 sq. m (227.5 sq. yd), and the largest is 335.13 sq. m (400.8 sq. yd). These drawing-derived values should be verified against the approved drawing. Layout record
Apartment carpet-area measurements, room dimensions and apartment floor plans are not applicable to this plotted offering in the supplied evidence. The available drawings are layout sheets, not individual home floor plans. Floor plans
5. Parking & vehicle circulation
No common parking area is allocated in the filed layout area statement (0.00 sq. m). No individual plot parking allocation, visitor parking provision, parking bay count, or vehicle entry and exit arrangement is established by the supplied records.
The layout approval identifies roads and requires them to remain open for access to neighbouring sites. It also lists internal road widths of 9.14 m and 12 m. These road provisions do not establish an exclusive parking entitlement for any plot.
6. Amenities, recreation & open spaces
The layout approval and filed drawing identify open space, social infrastructure and utility land. The approval’s conditions describe proposed infrastructure and amenity works; the supplied records do not verify their completion.
| Description / size | 1,230.05 sq. m, 9.05% in the drawing-derived area statement |
|---|---|
| Evidence source | Layout record |
| Declared progress / verified status | Reserved in the tentative layout; completion not independently verified |
| Description / size | 340.87 sq. m, 2.51% |
|---|---|
| Evidence source | Layout record |
| Declared progress / verified status | Area reserved; specific facility or completed use not established |
| Description / size | Named in layout-document amenity/utility text; no separate size supplied |
|---|---|
| Declared progress / verified status | Identified in filed material; completion not independently verified |
| Description / size | 3,209.86 sq. m, 23.62%; drawing lists 9.14 m and 12 m internal roads |
|---|---|
| Evidence source | Layout record |
| Declared progress / verified status | Provided for in layout; construction/completion not independently verified |
| Description / size | Approval requires handover by registered gift deed before release of the tentative layout |
|---|---|
| Declared progress / verified status | Requirement in approval conditions; completion of handover is not established here |
The layout approval also requires infrastructure and amenities to be completed within the stated period and identifies park development and avenue plantation among the proposed works. No independent completion evidence is supplied for those works.
7. Utilities, building services & safety
The tentative-layout approval describes proposed infrastructure including a water reservoir, septic tank or sewerage treatment plant, internal water-supply pipelines, overhead tank, electrical transformer and supply lines, street lights, solid-waste management, storm-water drains, underground drainage, rainwater-harvesting pits, park development and avenue plantation. It also requires the applicant to construct an overhead tank or sump, septic tank as applicable, and harvesting pits. These are approval-condition descriptions; the supplied evidence does not establish installed capacities or completed operation.
The RERA-filed amenity record marks water supply, sewerage, storm-water drains, street lighting, fire protection, electrical meter room/sub-station/receiving station, and water conservation/rainwater harvesting as listed provisions, but reports 0% progress for the entries. This does not establish completion. RERA amenities
No verified details are supplied for water source or storage capacity, STP capacity, electrical capacity or backup, EV charging, firefighting equipment, security systems, accessibility provisions, or completed commissioning. RERA amenities
8. Location, access & connectivity
The registered location is Vittaipally Tanda, Amangal, Ranga Reddy, Telangana 509321, on Survey Nos. 1400/P, 1401/P, 1402/P and 1404/P. The layout approval refers to Vitaipally Revenue Village and Amangal Mandal.
The approved layout identifies internal roads of 9.14 m and 12 m, a 30.00 m existing road and a 60.00 m proposed road. The supplied location record reports the nearest sampled Outer Ring Road interchange at approximately 39.9 km. No verified public-transport distances or journey times are provided. Location record
9. Developer & development status
The registered promoter is KOKKONDA ASHIS AND OTHERS, described in the RERA record as Others, with the organization described as four individuals. The supplied RERA registration certificate names the promoter and identifies the project; it does not provide a verified corporate-entity type or a fuller legal-entity identifier. RERA record RERA filing
Form B is an affidavit-cum-declaration signed by Kokkonda Ashish as an authorized signatory. It declares the land title basis, states that the land is free from encumbrances, and undertakes completion by 12 June 2026. These statements are promoter declarations.
The tentative layout approval places responsibility for layout development on the applicant and requires infrastructure and amenities to be completed within two years from approval, by 12 June 2026. The record supplied does not establish current physical completion, extension of the approval period, or a final layout release.
10. Approvals, official records & documents
| Record | Supplied evidence |
|---|---|
| TG-RERA registration | Form C registration certificate for RRR TOWNSHIP, registration P02400008591; validity stated as 06/08/2024–12/06/2026 |
| Tentative layout approval | Approval 0010/LO/3134/2024, dated 12 June 2024, issued by Amangal Municipality/Municipal Corporation for the layout on Survey Nos. 1400/P, 1401/P, 1402/P and 1404/P |
| Layout-plan filing | Layout-plan document with 41 plots and an area statement, filed under document ID 471476 |
| Promoter declaration | Form B affidavit-cum-declaration dated 22 July 2024, including the promoter’s completion undertaking |
| Individual occupancy/completion certificate | Not identified in the supplied documents Document index |
The tentative-layout approval expressly states that it is not proof of title and is subject to its conditions, including infrastructure development and transfer of designated areas by registered gift deed.
1. Project at a glance
Project identity
Registered project name: RRR TOWNSHIP
Project type: Plotted development / tentative layout
Phase or registered portion: Not separately identified; registration is for the project on the stated survey parcels
TG-RERA registration: P02400008591
Registration validity: Certificate states validity commencing 06/08/2024 and ending 12/06/2026; this is registration validity, not the current status of any extension
RERA status in supplied record: New project; certificate captured 10 September 2026. The supplied evidence does not establish whether registration has since been extended or otherwise changed
Registered promoter: KOKKONDA ASHIS AND OTHERS
Land and geographic identity
Locality: VITAIPALLY
Revenue village names in project records: Vittaipally Tanda (RERA certificate/header) and Vitaipally Revenue Village / Vitaipally Village (layout approval and title materials)
Mandal / district / PIN: Amangal / Ranga Reddy / 509321
Survey numbers and subdivisions: 1400/P, 1401/P, 1402/P and 1404/P
Site extent: 14,280.59 sq. m total; 693.71 sq. m affected by road widening; net area stated as 13,586.88 sq. m in the project land record
Boundaries: North: neighbours’ land; South: neighbours’ land; East: neighbours’ land; West: road
Development identity
Layout sanctioning authority: Amangal Municipality/Municipal Corporation; the filed layout material identifies TS-DTCP, delegated to Amangal Municipality
Principal approval: Tentative Layout Plan 0010/LO/3134/2024, approved 12 June 2024
Application number: 008479/LO/DTCP/3134/0016/2023
Layout configuration: 41 plots; no buildings or proposed built-up area are specified in the layout approval
Approved built-up area: 0.00 proposed built-up area, excluding and including parking, in the filed layout parameters; this is a plotted layout, not a building plan
Buildings, floors and parking levels: Not applicable or not disclosed for the plotted-layout approval; no building-floor or parking-level schedule is supplied
Offering and status
Offering: 41 individual plots in the tentative layout
Plot area range: Software-read from the approved drawing: 126.5–335.13 sq. m (151.3–400.8 sq. yd); drawing-derived measurements should be checked against the plan
Booked / available plots: Not established in the supplied RERA evidence
Construction stage: No independently verified on-site progress is supplied. The layout approval requires infrastructure and amenities to be completed by 12 June 2026
Promoter-declared completion: Form B undertakes completion by 12 June 2026
Occupancy / completion certificate: No occupancy or completion certificate is identified in the supplied documents; this is a plotted layout
2. The project story
RRR TOWNSHIP is a plotted residential layout, rather than an apartment or multi-tower development. The RERA certificate identifies the project at Vittaipally Tanda, Amangal, Ranga Reddy, PIN 509321, on Survey Nos. 1400/P, 1401/P, 1402/P and 1404/P. The layout approval describes the site as Vitaipally Revenue Village and records 41 plots.
The approved layout drawing allocates land to plots, internal roads, a park/open space, social infrastructure and utilities. The approval is tentative and makes infrastructure development and the handover of designated areas part of its conditions. The approval sets 12 June 2026 as the initial deadline for infrastructure and amenities; the promoter’s Form B separately declares the same completion date. These are filed/approval commitments, not independent verification that the works have been completed.
The RERA-filed records supplied here do not establish plot-by-plot sales status or current physical progress. No occupancy or completion certificate is provided.
3. Master plan, architecture & building design
This is a 41-plot layout. The filed layout records a site extent of 14,280.59 sq. m, a road-widening area of 693.71 sq. m, and a net layout area stated as 13,586.88 sq. m.
The layout drawing’s area statement, read by software, allocates the net layout area as follows. These are drawing-derived layout areas, not building or apartment areas:
| Layout use | Area | Share stated/read from drawing |
|---|---|---|
| Plots | 8,668.39 sq. m | 63.80% |
| Roads | 3,209.86 sq. m | 23.62% |
| Parks / organized open space | 1,230.05 sq. m | 9.05% |
| Social infrastructure | 340.87 sq. m | 2.51% |
| Utilities | 137.68 sq. m | 1.01% |
| Amenities | 0.00 sq. m | 0.00% |
The approval records internal road widths of 9.14 m and 12 m, as well as a 30.00 m existing road and a 60.00 m proposed road. It reserves plots 31–36 as mortgage plots in favour of the Municipality; the approval records a mortgage area of 1,772 sq. yd.
No building footprint, floors, tower arrangement, apartment plans or building-area schedule is evidenced. The filed layout parameters state proposed built-up area of 0.00 both excluding and including parking.
4. Homes, configurations & floor plans
The RERA-filed offering evidenced in the supplied records is 41 plots. No RERA plot-wise saleable-area schedule, booked/available inventory, or unit-by-unit allotment status is supplied.
The approved drawing’s plot schedule was read by software; its plot sizes are not presented as RERA-filed saleable areas. The drawing-derived size bands are:
150–200 sq. yd (125–167 sq. m): 15
200–250 sq. yd (167–209 sq. m): 9
250–300 sq. yd (209–251 sq. m): 6
300–400 sq. yd (251–334 sq. m): 10
400–500 sq. yd (334–418 sq. m): 1
The smallest software-read plot is 126.5 sq. m (151.3 sq. yd), the median is 190.21 sq. m (227.5 sq. yd), and the largest is 335.13 sq. m (400.8 sq. yd). These drawing-derived values should be verified against the approved drawing.
Apartment carpet-area measurements, room dimensions and apartment floor plans are not applicable to this plotted offering in the supplied evidence. The available drawings are layout sheets, not individual home floor plans.
5. Parking & vehicle circulation
No common parking area is allocated in the filed layout area statement (0.00 sq. m). No individual plot parking allocation, visitor parking provision, parking bay count, or vehicle entry and exit arrangement is established by the supplied records.
The layout approval identifies roads and requires them to remain open for access to neighbouring sites. It also lists internal road widths of 9.14 m and 12 m. These road provisions do not establish an exclusive parking entitlement for any plot.
6. Amenities, recreation & open spaces
The layout approval and filed drawing identify open space, social infrastructure and utility land. The approval’s conditions describe proposed infrastructure and amenity works; the supplied records do not verify their completion.
| Facility | Description / size | Evidence source | Declared progress / verified status |
|---|---|---|---|
| Park / open space | 1,230.05 sq. m, 9.05% in the drawing-derived area statement | Reserved in the tentative layout; completion not independently verified | |
| Social infrastructure | 340.87 sq. m, 2.51% | Area reserved; specific facility or completed use not established | |
| Tot-lot | Named in layout-document amenity/utility text; no separate size supplied | Identified in filed material; completion not independently verified | |
| Internal roads | 3,209.86 sq. m, 23.62%; drawing lists 9.14 m and 12 m internal roads | Provided for in layout; construction/completion not independently verified | |
| Open-space, roads and utility land to Municipality | Approval requires handover by registered gift deed before release of the tentative layout | Requirement in approval conditions; completion of handover is not established here |
The layout approval also requires infrastructure and amenities to be completed within the stated period and identifies park development and avenue plantation among the proposed works. No independent completion evidence is supplied for those works.
7. Utilities, building services & safety
The tentative-layout approval describes proposed infrastructure including a water reservoir, septic tank or sewerage treatment plant, internal water-supply pipelines, overhead tank, electrical transformer and supply lines, street lights, solid-waste management, storm-water drains, underground drainage, rainwater-harvesting pits, park development and avenue plantation. It also requires the applicant to construct an overhead tank or sump, septic tank as applicable, and harvesting pits. These are approval-condition descriptions; the supplied evidence does not establish installed capacities or completed operation.
The RERA-filed amenity record marks water supply, sewerage, storm-water drains, street lighting, fire protection, electrical meter room/sub-station/receiving station, and water conservation/rainwater harvesting as listed provisions, but reports 0% progress for the entries. This does not establish completion.
No verified details are supplied for water source or storage capacity, STP capacity, electrical capacity or backup, EV charging, firefighting equipment, security systems, accessibility provisions, or completed commissioning.
8. Location, access & connectivity
The registered location is Vittaipally Tanda, Amangal, Ranga Reddy, Telangana 509321, on Survey Nos. 1400/P, 1401/P, 1402/P and 1404/P. The layout approval refers to Vitaipally Revenue Village and Amangal Mandal.
The approved layout identifies internal roads of 9.14 m and 12 m, a 30.00 m existing road and a 60.00 m proposed road. The supplied location record reports the nearest sampled Outer Ring Road interchange at approximately 39.9 km. No verified public-transport distances or journey times are provided.
9. Developer & development status
The registered promoter is KOKKONDA ASHIS AND OTHERS, described in the RERA record as Others, with the organization described as four individuals. The supplied RERA registration certificate names the promoter and identifies the project; it does not provide a verified corporate-entity type or a fuller legal-entity identifier.
Form B is an affidavit-cum-declaration signed by Kokkonda Ashish as an authorized signatory. It declares the land title basis, states that the land is free from encumbrances, and undertakes completion by 12 June 2026. These statements are promoter declarations.
The tentative layout approval places responsibility for layout development on the applicant and requires infrastructure and amenities to be completed within two years from approval, by 12 June 2026. The record supplied does not establish current physical completion, extension of the approval period, or a final layout release.
10. Approvals, official records & documents
TG-RERA registration: Form C registration certificate for RRR TOWNSHIP, registration P02400008591; validity stated as 06/08/2024–12/06/2026
Tentative layout approval: Approval 0010/LO/3134/2024, dated 12 June 2024, issued by Amangal Municipality/Municipal Corporation for the layout on Survey Nos. 1400/P, 1401/P, 1402/P and 1404/P
Layout-plan filing: Layout-plan document with 41 plots and an area statement, filed under document ID 471476
Promoter declaration: Form B affidavit-cum-declaration dated 22 July 2024, including the promoter’s completion undertaking
Individual occupancy/completion certificate: Not identified in the supplied documents
The tentative-layout approval expressly states that it is not proof of title and is subject to its conditions, including infrastructure development and transfer of designated areas by registered gift deed.
Frequently asked questions
Is RRR TOWNSHIP registered with Telangana RERA?
Yes. RRR TOWNSHIP is registered with the Telangana Real Estate Regulatory Authority as P02400008591; the registration status is New Project.
Who is the developer of RRR TOWNSHIP?
The promoter named in the RERA registration is KOKKONDA ASHIS AND OTHERS.
Where is RRR TOWNSHIP located?
RRR TOWNSHIP is in VITAIPALLY, Vittaipally Tanda, Amangal, Rangareddy, Telangana (509321).
When will RRR TOWNSHIP be completed?
The promoter's proposed date of completion filed with RERA is 30/11/2026. This is the promoter's declaration, not a guarantee.
More projects in Amangal
